Clarity is an advanced chromatography station designed to acquire and evaluate data from up to four chromatographs at a time. Clarity - a top product in its category - represents a universal solution for laboratories. It enables the user to acquire data from any commercially available chromatograph with standard analogue output. Up to four chromatography systems, each of which can be equipped with up to four detectors, can be connected simultaneously. The chromatography station package includes an A/D converter (internal PCI card or external USB box) and the corresponding Clarity Software.

Algorithm for detection of peaks
Highly responsive algorithms enable users to detect hundreds of peaks in each chromatogram. Data from the analysis can naturally be reprocessed without the necessity of repeating the analysis.
Integration
All integration parameters are saved in the integration table. Parameters such as Peak Width and Threshold are programmable in time. There are a total of 27 integration parameters incorporated to ensure the optimal integration of peaks. Most of these parameters can be applied also with the mouse from icons on the toolbar. Every change of basic integration parameters in the chromatogram window will force immediate reintegration.
Method
All parameters for data acquisition and peak integration, including baseline operations and link to the calibration file are saved in the template method. After creating of a chromatogram, a copy of the template method becomes a part of the chromatogram file.
Multi-detector measurement
Once a measurement has been completed within the framework of one instrument and more than one detector (up to four), signals are simultaneously displayed and accompanied by a legend identifying each signal and detector. Users may select the number of signals displayed according to preference.
Calibration
The Clarity Station uses linked calibration. Calibration curves are saved in a separate file, to which the template and chromatogram methods are referring. After updating or modifying this calibration file, results in all chromatograms linked to this file will be automatically recalculated upon opening. Although the calibration is linked, the current states of the calibration file and methods are stored in the chromatogram every time it is saved (using the commands Save, Print or Export). The chromatogram with its former method settings and calibration curves may thus be opened from any prior saved state.
Calibration calculations
Clarity offers the ability to calculate using external or internal standard methods. There are six types of curves to fit calibration points with the option to include a zero point. The station allows you to select automatic or manual (interactive) method of data transmission from the calibration standard into the calibration file. Groups of peaks may also be calibrated.
Method of reference peaks
Use reference peaks and or customizable identification windows for individual peaks to enhance the accuracy of compound identification.
Editing and recalibration
Browsing and adjustment of calibration data is simple thanks to the consolidation of all compounds in a single global calibration table. The calibration table and curve of each substance is placed separately on the relevant tab in the main calibration window.
| TYPE |
PRODUCER |
NAME |
CONTROL |
STATUS |
| HPLC |
Agilent |
HP 1100 including DAD |
HPIB |
ready |
| HPLC |
Beckman
Coulter Inc. |
Altex 110A, 110B, 114 |
CB20 |
ready |
| HPLC |
Bio-Rad
Laboratories |
1350 |
CB20 |
ready |
| HPLC |
ECOM |
LCP 4020, LCP 4000 |
CB20 |
ready |
| HPLC |
ECOM |
LCP 4100 |
RS232 |
ready |
| HPLC |
ECOM |
Alpha10, Beta10, 50 |
RS232 - Uni |
ready |
| HPLC |
Flux
Instruments AG |
RHEOS 2000 |
RS232 |
ready |
| HPLC |
Gilson |
Pumps 302-307 |
GSIOC |
ready |
| HPLC |
Gynkotech |
M300CS, M480 |
CB20 |
ready |
| HPLC |
Knauer
GmbH |
Smartline 1000 |
RS232 - Uni |
ready |
| HPLC |
Knauer GmbH |
M64, K-501, K-500 |
CB20 |
ready |
| HPLC |
Lab
Alliance |
Pump Series III, 1500, 150 |
CB20, RS232 |
ready |
| HPLC |
Lab
Alliance |
Pump Series II, I, Q-Grad |
RS232 |
ready |
| HPLC |
Shimadzu
Ltd. |
LC-6A |
CB20 |
ready |
| HPLC |
Sykam |
S1021, S1122 |
CB20 |
ready |
| HPLC |
Unicam |
PU 4015 |
CB20 |
ready |
| HPLC |
Waters |
M 45, M 501, M 510, M 515 |
CB20 |
ready |
| HPLC |
- |
Any pumps with flow controlled by voltage or
frequency |
CB20 |
ready |
| HPLC |
- |
Any pump with on-line flow control by text
communication protocol |
RS232 - Uni |
ready |
| TYPE |
PRODUCER |
NAME |
CONTROL |
STATUS |
| AS |
Agilent |
7673 II, 7673 A, 7683 A |
RS232 |
ready |
| AS |
CTC
Analytics |
A200S |
RS232 |
ready |
| AS |
CTC
Analytics |
PAL (GC Part) |
RS232 |
ready |
| AS |
DANI |
ALS1000 |
RS232 |
ready |
| AS |
HTA |
HTA 300A, 300L |
RS232 |
ready |
| AS |
HTA |
200H |
RS232 |
ready |
| AS |
Spark
Holland |
Basic Marathon, Marathon-XT |
RS232 |
ready |
| AS |
Spark
Holland |
Midas, Endurance |
RS232 |
testing |
| TYPE |
PRODUCER |
NAME |
CONTROL |
STATUS |
| GC |
Agilent |
HP 5890 II, HP5890A, HP4890D |
RS232 |
ready |
| GC |
Agilent |
HP 6890, 6850, 6890N |
RS232 |
ready |
| GC |
Agilent |
6890N |
Ethernet |
ready |
| GC |
DANI |
GC1000 |
RS232 |
ready |
| GC |
Shimadzu |
GC17A |
RS203 |
ready |
|